TrialsgrambetaRCTs are beautiful

Wang CADe

2019

Real-time automatic detection system increases colonoscopic polyp and adenoma detection rates: a prospective randomised controlled study

In 1,058 patients undergoing diagnostic colonoscopy, real-time deep-learning polyp detection increased the adenoma detection rate compared with standard colonoscopy.

Result

Adenoma detection rate (ADR)
Absolute difference
8.8 points
NNT
12

Absolute difference and NNT are derived from the event rates.

Also reported: Adenomas per patient 0.53 vs 0.31 (P<0.001). Gain driven by diminutive adenomas (185 vs 102; P<0.001) with no difference in larger adenomas (77 vs 58; P=0.075); hyperplastic polyps also increased (114 vs 52; P<0.001).

Original publication
Subtopic
Adenoma detection
Design
Open-label RCT
Relevance
Important: one of several pillars.
Source
Wang P, et al. Gut. 2019;68(10):1813-1819.doi 10.1136/gutjnl-2018-317500

Discussion & critique

First randomised trial of real-time CADe and the proof of concept for the whole cluster. Open, non-blinded design in a low-ADR population; the gain came almost entirely from diminutive adenomas and hyperplastic polyps, so the clinical value, and the cost of the extra resections, was left for later trials to settle.