TrialsgrambetaRCTs are beautiful

Thiruvengadam CADe

2024

The Efficacy of Real-time Computer-aided Detection of Colonic Neoplasia in Community Practice: A Pragmatic Randomized Controlled Trial

In 1,100 patients undergoing colonoscopy in community practice, real-time computer-aided detection increased the adenoma detection rate compared with traditional colonoscopy.

Result

Adenoma detection rate (ADR)
Absolute difference
8.1 points
NNT
13

Absolute difference and NNT are derived from the event rates.

Also reported: Adenomas per colonoscopy 0.89 vs 0.60 (P<0.001); sessile serrated lesion detection 4.7% vs 2.0% (P=0.01). The ADR gain was confined to the first half of the trial (47.2% vs 33.7%; P=0.002) and absent in the second half (38.7% vs 34.9%; P=0.33).

Original publication
Subtopic
Adenoma detection
Design
Single-centre pragmatic RCT, community practice
Relevance
Important: one of several pillars.
Source
Thiruvengadam NR, et al. Clin Gastroenterol Hepatol. 2024;22(11):2221-2230.e15.doi 10.1016/j.cgh.2024.02.021

Discussion & critique

Primary endpoint met: CADe modestly raised ADR among average-detector community endoscopists, where real-world implementation studies had failed to show benefit. Single centre, open-label, a gain driven by <5 mm adenomas, and an effect that faded in the second half of the trial: a hint of novelty or learning effects that tempers the headline result.