TrialsgrambetaRCTs are beautiful

COLO-DETECT

2024

Polyp detection with colonoscopy assisted by the GI Genius artificial intelligence endoscopy module compared with standard colonoscopy in routine colonoscopy practice

In 2,032 adults undergoing screening or symptomatic colonoscopy, computer-aided detection increased mean adenomas per procedure compared with standard colonoscopy.

Result

Primary endpoint: Mean adenomas per procedure

Adenomas per procedure 1.56 vs 1.21 (adjusted mean difference 0.36, 95% CI 0.14–0.57; adjusted IRR 1.30, 95% CI 1.15–1.47; P<0.0001). ADR 56.6% vs 48.4% (difference 8.3%, 95% CI 3.9–12.7; aOR 1.47, 95% CI 1.21–1.78). Adverse events 25 vs 19, none attributed to the device.

Original publication
Subtopic
Adenoma detection
Design
Multicentre open-label pragmatic RCT, UK
Relevance
Important: one of several pillars.
Source
Seager A, et al. Lancet Gastroenterol Hepatol. 2024;9(10):911-923.doi 10.1016/S2468-1253(24)00161-4

Discussion & critique

The largest pragmatic CADe trial in routine practice and the UK evidence base for GI Genius, extending the Repici result to unselected NHS lists with screening and symptomatic indications. Open-label with unmasked colonoscopists, a polyp-count surrogate rather than cancer outcomes, imputation for missing outcome data, and Medtronic funding.