RACE II
2010
Rate Control Efficacy in Permanent Atrial Fibrillation: Lenient Versus Strict Rate Control II
In 614 patients with permanent atrial fibrillation, lenient rate control (resting heart rate <110 bpm) was non-inferior for a composite of cardiovascular events compared with strict rate control.
Result
- Absolute difference
- 2.0 points
difference-2.090% CI -7.6 to 3.5 · P < 0.001
The absolute difference is derived from the event rates.
- Subtopic
- rate control
- Design
- Open-label non-inferiority RCT
- Relevance
- Important: one of several pillars.
- Cited in
- ESC 2024 AFACC/AHA 2023 AF
- Source
- Van Gelder IC, et al. N Engl J Med. 2010;362(15):1363-1373.doi 10.1056/NEJMoa1001337
Discussion & critique
Event rates lower than expected and patients relatively young with preserved function, limiting generalisability. Established lenient rate control (<110 bpm) as an acceptable, simpler strategy in permanent AF.