TrialsgrambetaRCTs are beautiful

PROPPR

2015

Pragmatic, Randomized Optimal Platelet and Plasma Ratios

In 680 patients with severe trauma haemorrhage, a 1:1:1 plasma:platelet:RBC ratio did not change 24-hour or 30-day mortality versus 1:1:2, but reduced death from exsanguination at 24 hours.

Result

Primary endpoint: 24-hour and 30-day all-cause mortality

No mortality difference; less death from exsanguination at 24 h with 1:1:1.

Original publication
Subtopic
Trauma resuscitation
Design
Multicentre RCT, USA/Canada
Relevance
Important: one of several pillars.
Source
Holcomb JB, et al. JAMA. 2015;313(5):471-482.doi 10.1001/jama.2015.12

Discussion & critique

Best evidence for balanced-ratio massive-transfusion protocols.

Discussed in podcasts