MINT
2023
Myocardial Ischemia and Transfusion
In 3,504 patients with acute myocardial infarction and Hb <10 g/dL, a restrictive transfusion strategy (Hb <8) did not change 30-day death or recurrent MI versus a liberal strategy (Hb <10), with a trend toward harm.
Result
Efficacy: 30-day death or recurrent MIRR 1.15 (95% CI 0.99-1.34) · P = 0.07
Below 1 favours restrictive transfusion strategy (Hb <8), above 1 favours a liberal strategy (Hb <10).
- Absolute difference
- 2.4 points
The absolute difference is derived from the event rates.
Also reported: 6-mo data favour liberal.
- Subtopic
- Restrictive transfusion
- Design
- Multicentre RCT, USA
- Relevance
- Important: one of several pillars.
- Source
- Carson JL, et al. N Engl J Med. 2023;389(26):2446-2456.doi 10.1056/NEJMoa2307983
Discussion & critique
Carve-out from the Hb-7 default: in acute MI, target ~9–10 g/dL.