TrialsgrambetaRCTs are beautiful

MINT

2023

Myocardial Ischemia and Transfusion

In 3,504 patients with acute myocardial infarction and Hb <10 g/dL, a restrictive transfusion strategy (Hb <8) did not change 30-day death or recurrent MI versus a liberal strategy (Hb <10), with a trend toward harm.

Result

Efficacy: 30-day death or recurrent MIRR 1.15 (95% CI 0.99-1.34) · P = 0.07

Below 1 favours restrictive transfusion strategy (Hb <8), above 1 favours a liberal strategy (Hb <10).

Event rates
Absolute difference
2.4 points

The absolute difference is derived from the event rates.

Also reported: 6-mo data favour liberal.

Original publication
Subtopic
Restrictive transfusion
Design
Multicentre RCT, USA
Relevance
Important: one of several pillars.
Source
Carson JL, et al. N Engl J Med. 2023;389(26):2446-2456.doi 10.1056/NEJMoa2307983

Discussion & critique

Carve-out from the Hb-7 default: in acute MI, target ~9–10 g/dL.

Discussed in podcasts