DOSE-VF

2022

Double Sequential External Defibrillation

In 405 patients with refractory ventricular fibrillation, double sequential external defibrillation improved survival to hospital discharge versus standard defibrillation.

Result

Efficacy: Survival to hospital dischargeRR 2.21 (95% CI 1.33-3.67)

Below 1 favours standard defibrillation, above 1 favours double sequential external defibrillation.

Event rates
Absolute difference
17.1 points
NNT
6

Absolute difference and NNT are derived from the event rates.

Also reported: Vector change non-significant.

Original publication
Subtopic
Defibrillation
Design
Cluster-randomised crossover trial, Canada
Relevance
Important: one of several pillars.
Also listed in
Cardiac arrest & CPR
Source
Cheskes S, et al. N Engl J Med. 2022;387(21):1947-1956.doi 10.1056/NEJMoa2207304

Discussion & critique

Cluster-randomised so not perfectly individual-level, but the effect size is large enough to motivate practice change in refractory VF.