OptimPacing

2026

OptimPacing: Protection of Cardiac Function With Left Bundle Branch Pacing in Patients With Atrioventricular Block

In adults with second-degree or complete atrioventricular block, or ongoing atrial fibrillation, with a slow heart rate and related symptoms, left bundle branch pacing reduced death, heart failure hospitalisation or pacing-induced cardiomyopathy compared with right ventricular pacing.

Resultado

All-cause death, heart failure hospitalisation or pacing-induced cardiomyopathy (assessed at 6 to 36 months)
Diferença absoluta
10,7 pontos
Estimativa do efeito

59% lower risk59

A diferença absoluta deriva das taxas de eventos.

Também relatado: At four years, No patient developed pacing-induced cardiomyopathy with left bundle branch pacing vs 11.7% with right ventricular pacing. Heart failure hospitalisation occurred in 1.5% vs 2.9%.

Publicação original
Subtema
Conduction system pacing
Desenho
Double-blind randomised trial (First Affiliated Hospital of Nanjing Medical University; the programme calls it international and multicentre) of left bundle branch pacing versus right ventricular pacing in AV block with LVEF above 35%
Incluídos
685 doentes
Fonte
Qian Z, Jiang L, Hou X, et al. N Engl J Med. 2026; published online 8 November.doi 10.1056/nejmoa2612972

Discussão e crítica

In this randomised trial, left bundle branch pacing roughly halved a composite of death, heart failure hospitalisation and pacing-induced cardiomyopathy, and much of the gap came from cardiomyopathy, which did not occur at all with left bundle branch pacing. The trial was stopped early at a planned interim analysis after a median 3-year follow-up, which the investigators say may overstate the benefit and make the estimate less precise. The newsroom report gives no hazard ratio, confidence interval or P value, and it says only that the event committee was blinded, not patients or operators. Most participants had a normal ejection fraction and every left bundle branch procedure used the same lead type, so the results may not carry over to reduced heart function or to other pacing tools.

Discutido em podcasts