CONVINCE

Comparison of High-Dose Haemodiafiltration with High-Flux Haemodialysis

Patient / Population Intervention / Exposition Vergleich Endpunkt

In 1,360 prevalent haemodialysis patients, high-dose haemodiafiltration reduced all-cause mortality compared with conventional high-flux haemodialysis.

N
1.360
Design
International open-label RCT, median 30-month follow-up
Endpunkt
All-cause mortality
Relevanz
2
Ergebnis17.3% vs 21.9%; HR 0.77 (95% CI 0.65–0.93).
Blankestijn PJ, et al. N Engl J Med. 2023;389(8):700-709. 10.1056/NEJMoa2304820
Diskussion & Kritik

First clearly positive haemodiafiltration mortality trial; a relatively healthy European cohort limits generalisability.