IDEAL-AF
2026
Individually DEsigned Ablation of Low-voltage areas in patients with persistent Atrial Fibrillation — a randomised controlled multicentre trial
In 209 patients with persistent atrial fibrillation and low-voltage areas, pulmonary vein isolation plus individualised low-voltage ablation increased freedom from atrial arrhythmia at 12 months compared with pulmonary vein isolation alone.
Risultato
Efficacia: freedom from documented atrial arrhythmia (AF or AT) lasting >30 s off antiarrhythmic drugs at 12 months after one to two ablation procedures within 6 monthsOR 3,50 (IC 95% 1,98-6,20) · P < 0,001
Sotto 1 a favore di pulmonary vein isolation alone, sopra 1 a favore di pulmonary vein isolation plus individualised low-voltage ablation.
- Differenza assoluta
- 30,2 punti
- NNT
- 4
La differenza assoluta e l’NNT sono derivati dai tassi di eventi.
Riportato inoltre: Freedom from documented atrial arrhythmia off antiarrhythmic drugs at one year . AFEQT quality of life improved as well, with no safety concerns.
- Sottotema
- Ablation
- Disegno
- multicentre (5 Swedish ablation centres), patient-blinded RCT; 1:1 PVI plus low-voltage-zone ablation vs PVI alone; 90-day blanking; 12-month primary endpoint with smartphone ECG monitoring and Holter at 3 and 12 months; 2-year follow-up
- Rilevanza
- Importante: uno dei diversi pilastri.
- Fonte
- Paul Nordin A, Charitakis E, Carnlöf C, et al. Low-Voltage Ablation in Persistent Atrial Fibrillation: The IDEAL-AF Randomized Clinical Trial. JAMA. Published online August 30, 2026. doi:10.1001/jama.2026.17274doi 10.1001/jama.2026.17274
Discussione e critica
Substrate ablation beyond the pulmonary veins has failed trial after trial when the extra lesions were drawn by rule; here they are drawn by the individual atrium's low-voltage map, and the rhythm result is the largest in this field for years: 68% against 37% off drugs. Two things temper it: 209 patients at five Swedish centres, and an open-label design in which the intervention arm also received more ablation and more time on the table. The quality-of-life gain points the same way as the rhythm, which is not what the sham-controlled trial in this same session found for ablation generally.