HYPE
2020
Effect of a Machine Learning-Derived Early Warning System for Intraoperative Hypotension vs Standard Care on Depth and Duration of Intraoperative Hypotension During Elective Noncardiac Surgery: The HYPE Randomized Clinical Trial
In 68 adults undergoing elective non-cardiac surgery, a machine-learning hypotension early warning system with a treatment protocol reduced depth and duration of intra-operative hypotension compared with standard care targeting the same MAP ≥65 mmHg.
Result
Primary endpoint: Time-weighted average of hypotension (MAP <65 mmHg) during surgery
Median time-weighted average hypotension 0.10 vs 0.44 mmHg (median difference 0.38 mmHg, 95% CI 0.14–0.43; P=.001); median time in hypotension 8.0 vs 32.7 min (difference 16.7 min, 95% CI 7.7–31.0; P<.001). Serious adverse events resulting in death 0 vs 2 (7%).
- Subtopic
- Non-cardiac surgery
- Design
- Single-centre preliminary unblinded RCT, Netherlands
- Relevance
- Practice-defining: a trial the field needs to know.
- Source
- Wijnberge M, et al. JAMA. 2020;323(11):1052-1060.doi 10.1001/jama.2020.0592
Discussion & critique
The first randomised trial of the Hypotension Prediction Index, and proof of concept that predicting hypotension shortly before it occurs lets anaesthetists prevent it. Tiny, single-centre and unblinded, with a surrogate endpoint (hypotension burden) rather than organ injury, and 60 of 68 completed the trial. Maheshwari HPI, run with a different protocol, failed to replicate the effect, and Ripollés-Melchor HPI found no benefit on kidney injury.