Escobar Advance Alert Monitor
2020
Automated Identification of Adults at Risk for In-Hospital Clinical Deterioration
In 43,949 non-ICU hospitalisations reaching the alert threshold, automated deterioration alerts reviewed by remote nurses and escalated reduced 30-day mortality after an alert compared with usual care where the system was not yet deployed.
Result
Efficacy: Mortality within 30 days after an alertadjusted RR 0.84 (95% CI 0.78-0.90) · P < 0.001
Below 1 favours automated deterioration alerts reviewed by remote nurses and escalated, above 1 favours usual care where the system was not yet deployed.
Also reported: 30-day mortality after an alert lower in the intervention cohort ; 15,487 intervention vs 28,462 comparison hospitalisations, drawn from 548,838 non-ICU hospitalisations.
- Subtopic
- General deterioration
- Design
- Staggered deployment, non-randomised (19 hospitals)
- Relevance
- Supporting: context rather than must-know.
- Source
- Escobar GJ, et al. N Engl J Med. 2020;383(20):1951-1960.doi 10.1056/NEJMsa2001090
Discussion & critique
The first large-scale report that an automated, EHR-based deterioration model wired into a clinical workflow, remote nurse review plus rapid-response teams across Kaiser Permanente hospitals, was associated with lower mortality, and the template for later randomised tests such as CONCERN. Deployment was staggered but not randomised, so the comparison with not-yet-deployed hospitals rests on multivariable adjustment and is vulnerable to secular trends and site differences.