DANISH-CRT — Does Targeted LV Lead Positioning Towards Latest Local Electric Activation at CRT Implantation Reduce Incidence of the Combined Endpoint "Death or Non-planned Hospitalisation for Heart Failure" in Patients With HF and Prolonged QRS

In 1,000 patients with heart failure and bundle branch block receiving CRT, electrically targeted LV lead placement did not reduce death or unplanned heart-failure hospitalisation compared with conventional lead placement.

Resultado

Eficacia: Time to death or first non-planned hospitalisation for heart failureHR 1,10 (IC del 95% 0,86-1,39) · P = 0,45

Por debajo de 1 a favor de electrically targeted LV lead placement, por encima de 1 a favor de conventional lead placement.

Tasas de eventos
Diferencia absoluta
2,4 puntos

La diferencia absoluta se deriva de las tasas de eventos.

También se informa: Death or first unplanned heart-failure hospitalisation occurred in . Lead-related complications were more frequent in the targeted group.

Publicación original
Subtema
CRT lead placement
Diseño
Danish national multicentre (all five Danish university implanting centres), double-blind (patients and all study personnel except operating-room personnel masked), randomised 1:1 by block randomisation; CRT with the LV lead targeted by intra-procedural electrical mapping to the coronary-sinus branch with the latest local electrical activation versus conventional placement in a posterolateral, non-apical branch; superiority design, event-driven with minimum 2-year follow-up; modified intention-to-treat analysis, safety in all correctly assigned patients; enrolment 20 March 2018 to 3 June 2024, follow-up completed 27 February 2026; NCT03280862; sponsor Aarhus University Hospital.
Relevancia
Define la práctica: un ensayo imprescindible en la especialidad.
Fuente
Nielsen JC, et al. Lancet. 2026; published online 31 August. Presented at ESC Congress 2026, Hot Line 10.doi 10.1016/s0140-6736(26)01597-7

Discusión y crítica

Mapping the latest-activated segment and putting the lead there is the physiological argument for CRT made literal, and over nearly four years it bought nothing: the same events, a numerically worse hazard, and more lead complications for the trouble. Either the electrical target is not where the mechanical benefit lives, or conventional posterolateral placement already lands close enough often enough that a mapping step has no room to add. Blinded, event-driven and 1,000 patients: this is as clean a negative as CRT procedure trials get, and the investigators' conclusion against routine mapping should hold.